Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
1.
Prehosp Emerg Care ; 28(4): 598-608, 2024.
Article in English | MEDLINE | ID: mdl-38345309

ABSTRACT

BACKGROUND: An ambulance traffic crash not only leads to injuries among emergency medical service (EMS) professionals but also injures patients or their companions during transportation. We aimed to describe the incidence of ambulance crashes, seating location, seatbelt use for casualties (ie, both fatal and nonfatal injuries), ambulance safety efforts, and to identify factors affecting the number of ambulance crashes in Japan. METHODS: We conducted a nationwide survey of all fire departments in Japan. The survey queried each fire department about the number of ambulance crashes between January 1, 2017, and December 31, 2019, the number of casualties, their locations, and seatbelt usage. Additionally, the survey collected information on fire department characteristics, including the number of ambulance dispatches, and their safety efforts including emergency vehicle operation training and seatbelt policies. We used regression methods including a zero-inflated negative binomial model to identify factors associated with the number of crashes. RESULTS: Among the 726 fire departments in Japan, 553 (76.2%) responded to the survey, reporting a total of 11,901,210 ambulance dispatches with 1,659 ambulance crashes (13.9 for every 100,000 ambulance dispatches) that resulted in a total of 130 casualties during the 3-year study period (1.1 in every 100,000 dispatches). Among the rear cabin occupants, seatbelt use was limited for both EMS professionals (n = 3/29, 10.3%) and patients/companions (n = 3/26, 11.5%). Only 46.7% of the fire departments had an internal policy regarding seatbelt use. About three-fourths of fire departments (76.3%) conducted emergency vehicle operation training internally. The output of the regression model revealed that fire departments that conduct internal emergency vehicle operation training had fewer ambulance crashes compared to those that do not (odds of being an excessive zero -2.20, 95% CI: -3.6 to -0.8). CONCLUSION: Two-thirds of fire departments experienced at least one crash during the study period. The majority of rear cabin occupants who were injured in ambulance crashes were not wearing a seatbelt. Although efforts to ascertain seatbelt compliance were limited, Japanese fire departments have attempted a variety of methods to reduce ambulance crashes including internal emergency vehicle operation training, which was associated with fewer ambulance crashes.


Subject(s)
Accidents, Traffic , Ambulances , Seat Belts , Humans , Japan , Ambulances/statistics & numerical data , Accidents, Traffic/statistics & numerical data , Seat Belts/statistics & numerical data , Surveys and Questionnaires , Emergency Medical Services/statistics & numerical data , Female , Male
2.
J Emerg Med ; 66(2): 163-169, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38238230

ABSTRACT

BACKGROUND: Mask ventilation is a critical airway procedure made more difficult in the bearded patient. OBJECTIVE: We sought to objectively investigate whether application of transparent cling film (TegadermTM; 3M Healthcare, Maplewood, MN) over a beard in the operating room improves the quality of mask ventilation. METHODS: This was a randomized crossover trial of bearded adult patients undergoing surgery. Exclusions included emergency procedures, American Society of Anesthesiologists physical status classification > 3, a documented history of difficult mask ventilation, and body mass index (BMI) > 50. Transparent cling film was applied snuggly over the lower face with a 2- to 3-cm slit cut over the mouth after anesthesia induction. Mask ventilation performed by an anesthesiology resident, anesthesiology assistant, or anesthesiology assistant student and standardized to a thenar-eminence grip without use of airway adjuncts in a sniffing position. Standardized pressure-controlled ventilations were delivered via an anesthesia machine. A calibrated external pneumotachograph was used to measure delivered and returned tidal volumes from which raw and percent air leak were calculated. A clinically significant difference was determined a priori to be 15%, necessitating the enrollment of 25 patients. RESULTS: Of 25 subjects, 96% were men with a mean ± SD BMI of 29.3 ± 6. Seventeen (68%) had a full beard and 8 (32%) had a partial beard. The mean ± SD leakage was 48% ± 26% for transparent cling film vs. 46% ± 20% without its application, which was not significantly different (p = 0.67). CONCLUSIONS: The use of transparent cling film to cover the lower half of the bearded face did not have an impact on the ability or efficacy to perform mask ventilation in the operating room setting. CLINICALTRIALS: gov, Number NCT04274686.


Subject(s)
Laryngeal Masks , Respiration, Artificial , Adult , Male , Humans , Female , Respiration, Artificial/methods , Tidal Volume , Bandages , Hand , Face
4.
Prehosp Emerg Care ; 28(4): 545-557, 2024.
Article in English | MEDLINE | ID: mdl-38133523

ABSTRACT

Airway management is a cornerstone of emergency medical care. This project aimed to create evidence-based guidelines based on the systematic review recently conducted by the Agency for Healthcare Research and Quality (AHRQ). A technical expert panel was assembled to review the evidence using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) methodology. The panel made specific recommendations on the different PICO (population, intervention, comparison, outcome) questions reviewed in the AHRQ review and created good practice statements that summarize and operationalize these recommendations. The recommendations address the use of ventilation with bag-valve mask ventilation alone vs. supraglottic airways vs. endotracheal intubation for adults and children with cardiac arrest, medical emergencies, and trauma. Additional recommendations address the use of video laryngoscopy and drug-assisted airway management. These recommendations, and the associated good practice statements, offer EMS agencies and clinicians an opportunity to review the available evidence and incorporate it into their airway management strategies.


Subject(s)
Airway Management , Emergency Medical Services , Humans , Airway Management/methods , Airway Management/standards , Emergency Medical Services/standards , Emergency Medical Services/methods , Intubation, Intratracheal/standards , Intubation, Intratracheal/methods , Evidence-Based Medicine , Practice Guidelines as Topic
5.
Air Med J ; 42(6): 488-495, 2023.
Article in English | MEDLINE | ID: mdl-37996188

ABSTRACT

Postpartum hemorrhage is a relatively common and highly morbid complication of the postpartum period that often requires management by specialized providers at tertiary care facilities. Critical care transport teams may be tasked with transporting postpartum patients who are already experiencing postpartum hemorrhage, but they should also be aware that other peripartum patients may be at risk for developing postpartum hemorrhage while in the process of transport. As such, it is imperative that transport providers understand the signs, symptoms, causes, and complications of postpartum hemorrhage as well as the options for intervention and treatment. This article reviews the current clinical evidence regarding resuscitation and medical management strategies that transport teams should be familiar with as well as more advanced and invasive management techniques they may encounter and be expected to monitor during transport, such as balloon tamponade and aortic balloon occlusion.


Subject(s)
Postpartum Hemorrhage , Pregnancy , Female , Humans , Postpartum Hemorrhage/therapy , Treatment Outcome
6.
Air Med J ; 42(6): 483-487, 2023.
Article in English | MEDLINE | ID: mdl-37996187

ABSTRACT

In 1993, the Southwest found itself staring down a disease then known as "unexplained adult respiratory syndrome." During the outbreak, 12 of 23 known patients died. What we now recognize as hantavirus cardiopulmonary syndrome still remains a rare and deadly disease. Although no cure exists, modern supportive techniques such as extracorporeal membrane oxygenation have increased survival among these patients. Early diagnosis has become the primary factor in patient survival. The initial presentation of hantavirus is similar to acute respiratory distress syndrome, necessitating a high index of suspicion to afford the patient the best chance of survival. Diagnosis is further complicated by prolonged and nonspecific incubation periods making it difficult to pinpoint an exposure. Familiarizing oneself with common clinical presentations, diagnostic strategies, and testing is the best way to increase patient survival. Because hantavirus has a predilection for rural areas, transport to a tertiary facility is paramount to provide the resources necessary to care for these complex patients. Rapid sequence intubation, although common in airway-compromised patients, could prove fatal in the setting of the severe hemodynamic instability found in hantavirus cardiopulmonary syndrome. Anticipation of significant pressor use and fluid administration could likely mean the difference in patient mortality during transport.


Subject(s)
Hantavirus Infections , Hantavirus Pulmonary Syndrome , Orthohantavirus , Adult , Humans , Hantavirus Pulmonary Syndrome/diagnosis , Hantavirus Pulmonary Syndrome/therapy , Hantavirus Pulmonary Syndrome/complications , Hantavirus Infections/diagnosis , Hantavirus Infections/therapy , Hantavirus Infections/complications , Death , Critical Care
7.
Resuscitation ; 192: 109989, 2023 11.
Article in English | MEDLINE | ID: mdl-37805061

ABSTRACT

BACKGROUND: A multidisciplinary group of stakeholders were used to identify: (1) the core competencies of a training program required to perform in-hospital ECPR initiation (2) additional competencies required to perform pre-hospital ECPR initiation and; (3) the optimal training method and maintenance protocol for delivering an ECPR program. METHODS: A modified Delphi process was undertaken utilising two web based survey rounds and one virtual meeting. Experts rated the importance of different aspects of ECPR training, competency and governance on a 9-point Likert scale. A diverse, representative group was targeted. Consensus was achieved when greater than 70% respondents rated a domain as critical (> or = 7 on the 9 point Likert scale). RESULTS: 35 international ECPR experts from 9 countries formed the expert panel, with a median number of 14 years of ECMO practice (interquartile range 11-38). Participant response rates were 97% (survey round one), 63% (virtual meeting) and 100% (survey round two). After the second round of the survey, 47 consensus statements were formed outlining a core set of competencies required for ECPR provision. We identified key elements required to safely train and perform ECPR including skill pre-requisites, surrogate skill identification, the importance of competency-based assessment over volume of practice and competency requirements for successful ECPR practice and skill maintenance. CONCLUSIONS: We present a series of core competencies, training requirements and ongoing governance protocols to guide safe ECPR implementation. These findings can be used to develop training syllabus and guide minimum standards for competency as the growth of ECPR practitioners continues.


Subject(s)
Cardiopulmonary Resuscitation , Extracorporeal Membrane Oxygenation , Humans , Delphi Technique , Extracorporeal Membrane Oxygenation/methods , Cardiopulmonary Resuscitation/methods , Accreditation , Retrospective Studies
8.
Air Med J ; 42(2): 110-118, 2023.
Article in English | MEDLINE | ID: mdl-36958874

ABSTRACT

Upper gastrointestinal bleeding is a relatively common and life-threatening condition encountered by critical care transport crews. It is of paramount importance that transport crews understand the underlying pathophysiology of variceal and nonvariceal gastrointestinal bleeding as well as the nuanced management of this patient population. This article reviews the current clinical evidence on initial resuscitation, medical management, and advanced invasive therapies (such as balloon tamponade devices) that transport crews should be familiar with to manage these patients. In addition, we present a novel method of continuous balloon pressure monitoring of balloon tamponade devices that is applicable to the transport environment.


Subject(s)
Critical Care , Gastrointestinal Hemorrhage , Humans , Gastrointestinal Hemorrhage/therapy , Gastrointestinal Hemorrhage/epidemiology , Acute Disease , Resuscitation
9.
Prehosp Emerg Care ; 27(1): 94-100, 2023.
Article in English | MEDLINE | ID: mdl-34874807

ABSTRACT

OBJECTIVE: Rules and regulations for ambulance operations differ across countries and regions, however, little is known about ambulance crashes outside of the United States. Japan is unique in several aspects, for example, routine use of lights and sirens during response and transport regardless of the urgency of the case and low speed limits for ambulances. The aim of this study was to describe the incidence and characteristics of ambulance crashes in Japan. METHODS: We retrospectively analyzed data from the Institute for Traffic Accident Research and Data Analysis (ITARDA) that include all traffic crashes resulting in injury or death in Japan. The study included all ambulance crashes from 2009 to 2018. We compared crashes that occurred during emergency operations with lights and sirens (i.e., when responding to a call or transporting a patient) to those that occurred during non-emergency operations without lights or sirens. We also used data on total number of ambulance dispatches from the Japanese Fire and Disaster Management Agency to calculate ambulance crash risk. RESULTS: During the 10-year period, we identified a total of 486 ambulance crashes out of 59,208,761 ambulance dispatches (0.82 in every 100,000 dispatches or one crash for every 121,829 dispatches) that included two fatal crashes. Among all ambulance crashes, 142 (29.2%) occurred during emergency operations. The incidence of ambulance crashes decreased significantly over the 10-year period. Ambulance crashes at an intersection occurred more frequently during emergency operations than during non-emergency operations (72.5% vs. 58.1%; 14.4% difference, 95% CI 5.0-22.9). CONCLUSIONS: Ambulance crashes occurred infrequently in Japan with crash rates much lower than previously reported crash rates in the United States. Ambulance crashes during emergency operations occurred more frequently at intersections compared to non-emergency operations. Further investigation of the low Japanese ambulance crash rates could provide opportunities to improve ambulance safety in other countries.


Subject(s)
Automobile Driving , Emergency Medical Services , Humans , Accidents, Traffic , Ambulances , Retrospective Studies , Japan
10.
Prehosp Emerg Care ; 27(1): 107-111, 2023.
Article in English | MEDLINE | ID: mdl-34990301

ABSTRACT

Point-of-Care Ultrasound (POCUS) has been demonstrated to have multiple applications in the care of critically ill and injured patients, especially given its portability and ease of use. These characteristics of POCUS make it ideal for use in the prehospital environment as well. We present a case that highlights a novel application of ultrasound in the prehospital management of out-of-hospital cardiac arrest (OHCA).


Subject(s)
Cardiopulmonary Resuscitation , Emergency Medical Services , Out-of-Hospital Cardiac Arrest , Humans , Paramedics , Out-of-Hospital Cardiac Arrest/diagnostic imaging , Out-of-Hospital Cardiac Arrest/therapy , Return of Spontaneous Circulation , Carotid Arteries
11.
Prehosp Emerg Care ; 27(2): 184-191, 2023.
Article in English | MEDLINE | ID: mdl-35639014

ABSTRACT

The duration of low flow prior to initiation of extracorporeal cardiopulmonary resuscitation (eCPR) appears to influence survival. Strategies to reduce the low-flow interval for out-of-hospital cardiac arrest have been focused on expediting patient transport to the hospital or initiating extracorporeal support in the prehospital setting. To date, a direct comparison of low-flow interval between these strategies has not been made. To attempt this comparison, a model was created to predict low-flow intervals for each strategy at different locations across the city of Albuquerque, New Mexico. The data, specific to Albuquerque, suggest that a prehospital cannulation strategy consistently outperforms an expedited transport strategy, with an estimated difference in low-flow interval of 34.3 to 37.2 minutes, depending on location. There is no location within the city in which an expedited transport strategy results in a shorter low-flow interval than prehospital cannulation. It would be rare to successfully initiate eCPR by either strategy in fewer than 30 minutes from the time of patient collapse. Using a prehospital cannulation strategy, the entire coverage area could be eligible for eCPR within 60 minutes of patient collapse. The use of predictive modeling can be a low-cost solution to assist with strategic deployment of prehospital resources and may have potential for real-time decision support for prehospital clinicians.


Subject(s)
Cardiopulmonary Resuscitation , Emergency Medical Services , Extracorporeal Membrane Oxygenation , Out-of-Hospital Cardiac Arrest , Humans , Emergency Medical Services/methods , Time Factors , Cardiopulmonary Resuscitation/methods , Out-of-Hospital Cardiac Arrest/therapy , Retrospective Studies
12.
Air Med J ; 41(6): 526-529, 2022.
Article in English | MEDLINE | ID: mdl-36494167

ABSTRACT

For decades, most prehospital clinicians have only been armed with needle thoracostomy to treat a tension pneumothorax, which has a significant failure rate. Following recent changes by the US military, more ground and air transport agencies are adopting simple thoracostomy, also commonly referred to as finger thoracostomy, as a successful alternative. However, surgical procedures performed by prehospital clinicians remain uncommon, intimidating, and challenging. Therefore, it is imperative to adopt a training strategy that is comprehensive, concise, and memorable to best reduce cognitive load on clinicians while in a high-acuity, low-frequency situation. We suggest the following mnemonic to aid in learning and retention of the key procedural steps: FINGER (Find landmarks; Inject lidocaine/pain medicine; No infection allowed; Generous incision; Enter pleural space; Reach in with finger, sweep, reassess). This teaching aid may help develop and maintain competence in the simple thoracostomy procedure, leading to successful treatment of both a tension pneumothorax and hemothorax.


Subject(s)
Military Personnel , Pneumothorax , Humans , Thoracostomy/methods , Pneumothorax/surgery , Hemothorax
13.
Air Med J ; 41(1): 133-140, 2022.
Article in English | MEDLINE | ID: mdl-35248332

ABSTRACT

Morbidly and super obese patients are a unique patient population that presents critical care transport providers with unique clinical and logistical challenges in the setting of respiratory distress and failure. These patients are more likely to have chronic respiratory issues at baseline, unique anatomic and physiologic abnormalities, and other comorbidities that leave them poorly able to tolerate respiratory illness or injury. This requires specialized understanding of their respiratory mechanics as well as how to tailor standard treatment modalities, such as noninvasive ventilation, to meet their needs. Also, careful and deliberate planning is required to address the specific anatomic and physiologic characteristics of this population if intubation and mechanical ventilation are needed. Finally, their dimensions and weight also have distinct consequences on transport vehicle considerations. This article reviews the pathophysiology, management, and critical care transport considerations for this unique patient population in respiratory distress and failure.


Subject(s)
Noninvasive Ventilation , Respiratory Distress Syndrome , Respiratory Insufficiency , Critical Care , Humans , Noninvasive Ventilation/methods , Obesity , Respiration, Artificial , Respiratory Distress Syndrome/therapy , Respiratory Insufficiency/therapy
14.
Prehosp Emerg Care ; 26(sup1): 32-41, 2022.
Article in English | MEDLINE | ID: mdl-35001830

ABSTRACT

Supraglottic airway (SGA) devices provide effective conduits for oxygenation and ventilation and may offer protection from gastric aspiration. SGA devices are widely used by EMS clinicians as both rescue and primary airway management devices. While in common use for more than four decades, major developments in SGA education, science, and technology have influenced clinical strategies of SGA insertion and use in prehospital airway management for patients of all ages. NAEMSP recommends:SGAs have utility as a primary or secondary EMS airway intervention. EMS agencies should select SGA strategies that best suit available resources and local clinician skillset, as well as the nature of their clinical practice setting.EMS agencies that perform endotracheal intubation must also equip their clinicians with SGA devices and ensure adequate training and competence.In select situations, drug-assisted airway management may be used by properly credentialed EMS clinicians to facilitate SGA insertion.Confirmation of initial and continuous SGA placement using waveform capnography is strongly encouraged as a best practice.When it is functioning properly, EMS clinicians should refrain from converting an SGA to an endotracheal tube. The decision to convert an SGA to an endotracheal tube must consider the patient's condition, the effectiveness of SGA ventilations, and the clinical context and course of initial SGA insertionSGA training, competency, and clinical use must be continuously evaluated by EMS agencies using focused quality management programs.


Subject(s)
Emergency Medical Services , Airway Management , Capnography , Humans , Intubation, Intratracheal
15.
J Intensive Care Med ; 37(7): 917-924, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34541951

ABSTRACT

Purpose: Data on the use of transesophageal echocardiography (TEE) by intensivist physicians (IP) and emergency physicians (EP) are limited. This study aims to characterize the use of TEE by IPs and EPs in critically ill patients at a single center in the United States. Materials and Methods: Retrospective chart review of all critical care TEEs performed from January 1, 2016 to January 31, 2021. The personnel performing the exams, location of the exams, characteristics of exams, complications, and outcome of the patients were reviewed. Results: A total of 396 examinations was reviewed. TEE was performed by IPs (92%) and EPs (9%). The location of TEE included: intensive care unit (87%), emergency department (11%), and prehospital (2%) settings. The most common indications for TEE were: hemodynamic instability/shock (44%), cardiac arrest (23%), and extracorporeal membrane oxygenation (ECMO) facilitation, adjustment, or weaning (21%). The most common diagnosis based on TEE were: normal TEE (25%), left ventricular dysfunction (19%), and vasodilatory shock (15%). A management change resulted from 89% of exams performed. Complications occurred in 2% of critical care TEEs. Conclusion: TEE can be successfully performed by IPs and EPs on critically ill patients in multiple clinical settings. TEE frequently informed management changes with few complications.


Subject(s)
Critical Illness , Physicians , Critical Care , Critical Illness/therapy , Echocardiography, Transesophageal/adverse effects , Humans , Retrospective Studies
16.
Shock ; 57(1): 7-14, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34033617

ABSTRACT

Hemorrhage, and particularly noncompressible torso hemorrhage remains a leading cause of potentially preventable prehospital death from trauma in the United States and globally. A subset of severely injured patients either die in the field or develop irreversible hemorrhagic shock before they can receive hospital definitive care, resulting in poor outcomes. The focus of this opinion paper is to delineate (a) the need for existing trauma systems to adapt so that potentially life-saving advanced resuscitation and truncal hemorrhage control interventions can be delivered closer to the point-of-injury in select patients, and (b) a possible mechanism through which some trauma systems can train and incorporate select prehospital advanced resuscitative care teams to deliver those interventions.


Subject(s)
Emergency Medical Services/organization & administration , Hemorrhage/therapy , Resuscitation , Humans , Patient Care Team , Torso , Triage
17.
J Emerg Med ; 61(5): 550-557, 2021 11.
Article in English | MEDLINE | ID: mdl-34736797

ABSTRACT

BACKGROUND: The administration of sedation and neuromuscular blockade to facilitate extraglottic device (EGD) placement is known as rapid sequence airway (RSA). In the emergency department (ED), EGDs are used largely as rescue devices. In select patients, there may be significant advantages to using EGDs over laryngoscopy as the primary airway device in the ED. OBJECTIVE: Our study sought to describe the practice of RSA in the ED, including rates of successful oxygenation, ventilation, and complications from EGD use. METHODS: We identified patients in the ED between 2007 and 2017 who underwent RSA with the LMA® Fastrach™ (hereafter termed ILMA; Teleflex Medical Europe Ltd., Athlone, Ireland) placed as the first definitive airway management device. A trained abstractor performed chart and video review of the cases to determine patient characteristics, physician use of the ILMA, indication for ILMA placement, success of oxygenation and ventilation, success of intubation, and complications related to the device. RESULTS: During the study period, 94 patients underwent RSA with the ILMA. Of those, 93 (99%) were successfully oxygenated and ventilated, and when intubation was attempted, 89% were able to be intubated through the ILMA. The incidence of vomiting and aspiration was 1% and 3%, respectively. There were 30 different attending physicians who supervised RSA and the median number was 2 per physician in the 10-year study period. CONCLUSION: The practice of RSA with the ILMA in the ED is associated with a high rate of successful oxygenation, ventilation, and intubation with infrequent complications, even when performed by physicians with few experiences in the approach.


Subject(s)
Laryngeal Masks , Airway Management , Emergency Service, Hospital , Humans , Intubation, Intratracheal , Laryngoscopy
19.
J Am Coll Emerg Physicians Open ; 2(2): e12390, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33718924

ABSTRACT

OBJECTIVES: Health care workers experience an uncertain risk of aerosol exposure during patient oxygenation. To improve our understanding of these risks, we sought to measure aerosol production during various approaches to oxygenation in healthy volunteers in an emergency department. METHODS: This was a prospective study conducted in an empty patient room in an academic ED. The room was 10 ft. long x 10 ft. wide x 9 ft. tall (total volume 900 ft3) with positive pressure airflow (1 complete turnover of air every 10 minutes). Five oxygenation conditions were used: humidified high-flow nasal cannula (HFNC) at 3 flow rates [15, 30, and 60 liters per minute (LPM)], non-rebreather mask (NRB) at 1 flow rate (15 LPM), and closed-circuit continuous positive airway pressure (CPAP) using the ED ventilator; in all cases a simple procedural mask was used. The NRB and HFNC at 30 LPM maneuvers were also repeated without the procedural mask, and CPAP was applied both with and without a filter. Each subject then sequentially underwent 8 total oxygenation conditions, always in the same order. Each oxygenation condition was performed with the participant on a standard ED bed. Particles were measured by laser aerosol spectrometer, with the detector sampling port positioned directly over the center of the bed, 0.35 meters away and at a 45-degree angle from the subject's mouth. Each approach to oxygenation was performed for 10 minutes, followed by a 20-minute room washout (≈ 2 complete room air turnovers). Particle counts were summated for 2 size ranges (150-300 nm and 0.5-2.0 µm) and compared before, during, and after each of the 8 oxygenation conditions. RESULTS: Eight adult subjects were enrolled (mean age 42 years, body mass index 25). All subjects completed 8 oxygenation procedures (64 total). Mean particle counts per minute across all oxygenation procedures was 379 ± 112 (mean ± SD) for smaller aerosols (150-300 nm) and 9.3 ± 4.6 for larger aerosols (0.5-2.0 µm). HFNC exhibited a flow-dependent increase in particulate matter (PM) generation-at 60 LPM, HFNC had a substantial generation of small (55% increase) and large particles (70% increase) compared to 15 LPM. CPAP was associated with lowered small and large particle generation (≈ 10-15% below baseline for both sizes of PM). A patient mask limited particle generation with the NRB, where it was associated with a reduction in small and large particulates (average 40% and 20% lower, respectively). CONCLUSION: Among 3 standard oxygenation procedures, higher flow rates generally were associated with greater production of both small and large aerosols. A patient mask lowered aerosol counts in the NRB only. Protocol development for oxygenation application should consider these factors to increase health care worker safety.

20.
J Am Coll Emerg Physicians Open ; 2(2): e12389, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33728418

ABSTRACT

OBJECTIVE: Air medical transport of patients with known or suspected coronavirus disease 2019 (COVID-19) likely represents a high-risk exposure to crew members as aircraft cabins are quite small resulting in close personal contact. The actual risk to medical crew members is not known. METHODS: We conducted an institutional review board-exempt, retrospective study of air medical transport of patients with known or suspected COVID-19 by 8 programs in the Four Corners Region to determine the number of symptomatic COVID-19 among air medical crew members compared to total exposure time. All programs used similar routine personal protective equipment (PPE), including N-95 masks and eye protection. Total exposure time was considered from time of first patient contact until handoff at a receiving hospital. RESULTS: There were 616 air transports: 62% by fixed-wing and 38% by rotor-wing aircraft between March 15 and September 6, 2020. Among transported patients, 407 (66%) were confirmed COVID+ and 209 (34%) were under investigation. Patient contact time ranged from 38 to 432 minutes with an average of 140 minutes. The total exposure time for medical crew was 2924 hours; exposure time to confirmed COVID+ patients was 2008 hours. Only 30% of patients were intubated, and the remainder had no oxygen (8%), low-flow nasal cannula (42%), mask (11%), high-flow nasal cannula (4.5%), and continuous positive airway pressure or bilevel positive airway pressure (3.5%). Two flight crew members out of 108 developed COVID that was presumed related to work. CONCLUSIONS: Air medical transport of patients with known or suspected COVID-19 using routine PPE is considered effective for protecting medical crew members, even when patients are not intubated. This has implications for health care personnel in any setting that involves care of patients with COVID-19 in similarly confined spaces.

SELECTION OF CITATIONS
SEARCH DETAIL
...